最優質的 Junos Troubleshooting - JN0-690 考古題
在IT世界裡,擁有 Juniper Junos Troubleshooting - JN0-690 認證已成為最合適的加更簡單的方法來達到成功。這意味著,考生應努力通過考試才能獲得 Junos Troubleshooting - JN0-690 認證。我們很好地體察到了你們的願望,並且為了滿足廣大考生的要求,向你們提供最好的 Juniper Junos Troubleshooting - JN0-690 考古題。如果你選擇了我們的 Juniper Junos Troubleshooting - JN0-690 考古題資料,你會覺得拿到 Juniper 證書不是那麼難了。
我們網站每天給不同的考生提供 Juniper Junos Troubleshooting - JN0-690 考古題數不勝數,大多數考生都是利用了 Junos Troubleshooting - JN0-690 培訓資料才順利通過考試的,說明我們的 Juniper Junos Troubleshooting - JN0-690 題庫培訓資料真起到了作用,如果你也想購買,那就不要錯過,你一定會非常滿意的。一般如果你使用 Juniper Junos Troubleshooting - JN0-690 針對性復習題,你可以100%通過 Junos Troubleshooting - JN0-690 認證考試。
為 Junos Troubleshooting - JN0-690 題庫客戶提供跟踪服務
我們對所有購買 Juniper Junos Troubleshooting - JN0-690 題庫的客戶提供跟踪服務,確保 Juniper Junos Troubleshooting - JN0-690 考題的覆蓋率始終都在95%以上,並且提供2種 Juniper Junos Troubleshooting - JN0-690 考題版本供你選擇。在您購買考題後的一年內,享受免費升級考題服務,並免費提供給您最新的 Juniper Junos Troubleshooting - JN0-690 試題版本。
Juniper Junos Troubleshooting - JN0-690 的訓練題庫很全面,包含全真的訓練題,和 Juniper Junos Troubleshooting - JN0-690 真實考試相關的考試練習題和答案。而售後服務不僅能提供最新的 Juniper Junos Troubleshooting - JN0-690 練習題和答案以及動態消息,還不斷的更新 Junos Troubleshooting - JN0-690 題庫資料的題目和答案,方便客戶對考試做好充分的準備。
購買後,立即下載 JN0-690 試題 (Junos Troubleshooting): 成功付款後, 我們的體統將自動通過電子郵箱將你已購買的產品發送到你的郵箱。(如果在12小時內未收到,請聯繫我們,注意:不要忘記檢查你的垃圾郵件。)
擁有超高命中率的 Junos Troubleshooting - JN0-690 題庫資料
Junos Troubleshooting 題庫資料擁有有很高的命中率,也保證了大家的考試的合格率。因此 Juniper Junos Troubleshooting-JN0-690 最新考古題得到了大家的信任。如果你仍然在努力學習為通過 Junos Troubleshooting 考試,我們 Juniper Junos Troubleshooting-JN0-690 考古題為你實現你的夢想。我們為你提供最新的 Juniper Junos Troubleshooting-JN0-690 學習指南,通過實踐的檢驗,是最好的品質,以幫助你通過 Junos Troubleshooting-JN0-690 考試,成為一個實力雄厚的IT專家。
我們的 Juniper Junos Troubleshooting - JN0-690 認證考試的最新培訓資料是最新的培訓資料,可以幫很多人成就夢想。想要穩固自己的地位,就得向專業人士證明自己的知識和技術水準。Juniper Junos Troubleshooting - JN0-690 認證考試是一個很好的證明自己能力的考試。
在互聯網上,你可以找到各種培訓工具,準備自己的最新 Juniper Junos Troubleshooting - JN0-690 考試,但是你會發現 Juniper Junos Troubleshooting - JN0-690 考古題試題及答案是最好的培訓資料,我們提供了最全面的驗證問題及答案。是全真考題及認證學習資料,能夠幫助妳一次通過 Juniper Junos Troubleshooting - JN0-690 認證考試。
最新的 JNCSP-SEC JN0-690 免費考試真題:
1. -- Exhibit -[edit] user@R1# run show interfaces ge-1/1/2 terse Interface Admin Link Proto Local Remote ge-1/1/2 up up ge-1/1/2.0 up up aenet --> ae0.0
[edit] user@R1# run show interfaces ge-1/1/3 terse Interface Admin Link Proto Local Remote ge-1/1/3 up up ge-1/1/3.0 up up aenet --> ae0.0
[edit]
user@R1# run show interfaces ae0 terse
Interface Admin Link Proto Local Remote
ae0 up down
ae0.0 up down bridge
[edit]
user@R1# show interfaces ae0
aggregated-ether-options {
lacp {
periodic slow;
system-priority 200;
}
}
unit 0 {
family bridge {
interface-mode trunk;
vlan-id-list 100;
}
}
**************************************************************************
[edit]
user@R2# run show interfaces ge-1/1/2 terse
Interface Admin Link Proto Local Remote
ge-1/1/2 up up
ge-1/1/2.0 up up aenet --> ae0.0
[edit]
user@R2# run show interfaces ge-1/1/3 terse
Interface Admin Link Proto Local Remote
ge-1/1/3 up up
ge-1/1/3.0 up up aenet --> ae0.0
[edit]
user@R2# run show interfaces ae0 terse
Interface Admin Link Proto Local Remote
ae0 up down
ae0.0 up down bridge
[edit]
user@R2# show interfaces ae0
aggregated-ether-options {
lacp {
periodic fast;
system-priority 100;
}
}
unit 0 {
family bridge {
interface-mode trunk;
vlan-id-list 100;
}
}
-- Exhibit --
You have configured a LAG and are now enabling LACP on the ae0 interface. You have configured and committed the configuration as shown in the exhibit. However, the exhibit also shows that the ae0 interface is now in the up/down state.
What must you do to resolve this problem?
A) Change the LACP system-priority of R1 to 300.
B) Configure R2's LACP configuration as passive.
C) Configure both routers' ae0 LACP configuration to periodic fast.
D) Configure R1's LACP configuration as active.
2. Which two actions are required when performing a unified in-service software upgrade (ISSU)? (Choose two.)
A) You must disable graceful Routing Engine switchover (GRES) if the Layer 2 Control Protocol is in use.
B) You must enable nonstop active routing (NSR).
C) You must disable nonstop bridging (NSB) if the Layer 2 Control Protocol is in use.
D) You must enable graceful Routing Engine switchover (GRES).
3. Click the Exhibit button.
-- Exhibit -user@r2# run show route 100.1.1.0/24 detail
inet.0: 5 destinations, 5 routes (5 active, 0 holddown, 0 hidden)
100.1.1.0/24 (1 entry, 1 announced) *Static PreferencE. 5 Next hop typE. Reject Address: 0x8f7b5a4 Next-hop reference count: 2 StatE. Local AS: 65001 AgE. 59 Task: RT Announcement bits (1): 2-KRT AS path: 65005 I
user@r2# show protocols bgp
group ibgp { type external; export to-bgp; neighbor 10.1.2.1 { local-address 10.1.2.2; family inet { unicast; } family inet6 { unicast; } peer-as 65005; }
}
user@r2# run show bgp summary Groups: 1 Peers: 1 Down peers: 0 Table Tot Paths Act Paths Suppressed History Damp State Pending inet6.0
0 0 0 0 0 0 inet.0 0 0 0 0 0 0 Peer AS InPkt OutPkt OutQ Flaps Last Up/Dwn State|#Active/Received/Accepted/Damped...
10.1.2.1 65005 31 31 0 0 12:08 Establ inet6.0: 0/0/0/0 inet.0: 0/0/0/
user@r2# show policy-options
policy-statement to-bgp { from protocol static; then accept;
}
user@r2# run show route advertising-protocol bgp 10.1.2.1
[edit] user@r2# -- Exhibit -
Referring to the exhibit, router r2 does not advertise the static route to peer 10.1.2.1. What is the problem?
A) An AS path loop is detected.
B) The export policy should be applied under the [edit protocols bgp group ibgp neighbor 10.1.2.1] hierarchy.
C) The export policy is incorrect.
D) The static route has Next hop typE. Reject.
4. What controls the CLI process?
A) chassis control daemon
B) routing protocol process
C) management daemon
D) device control daemon
5. Which three statements are true about performing an ISSU on a Junos device? (Choose three.)
A) The backup RE verifies disk space on both REs, unsupported configurations, and unsupported PICs.
B) Any unsupported PICs will cause the ISSU process to fail with "Error: incompatible hardware detected."
C) The master RE verifies disk space on both REs, unsupported configurations, and unsupported PICs.
D) ksyncd synchronizes the kernel on the backup RE with the master RE.
E) Every PFE on each FPC downloads the new software from the backup RE.
問題與答案:
問題 #1 答案: D | 問題 #2 答案: B,D | 問題 #3 答案: A | 問題 #4 答案: C | 問題 #5 答案: C,D,E |
59.120.61.* -
你們的服務和題考古題都不錯,幫助我通過了這次的考試,JN0-690考試真的很難,還好有你們的幫助,謝謝!